Repair
3A2098H 83
Replace Transducer O-Rings
1. Prepare Fluid Plate Assembly for Repair, page
80.
2. Remove the fluid outlet pressure sensor (117) from
the regulator (108).
3. Press the transducer (CG) out of the retainer nut
(CH).
4. Remove the faulty o-ring (120) and replace with
new.
5. Press the transducer back into the retainer nut.
6. Reconnect the fluid outlet pressure sensor to the
regulator.
F
IG
. 55
F
IG
. 56
117
108
r_pf0000_313377_16a
120
CH
CG