Graco 313855H Manual de usuario

Busca en linea o descarga Manual de usuario para Otros dispositivos de entrada Graco 313855H. Graco 313855H User's Manual Manual de usuario

  • Descarga
  • Añadir a mis manuales
  • Imprimir
  • Pagina
    / 36
  • Tabla de contenidos
  • SOLUCIÓN DE PROBLEMAS
  • MARCADORES
  • Valorado. / 5. Basado en revisión del cliente
Vista de pagina 0
Instructions
GLC 4400
Lubrication Controller
313855H
For controlling and monitoring single-line resistive, parallel, series progressive and dual
line, automatic lubrication systems. Not for use in explosive atmospheres!
Part No.: 24B591, Series C: DC Power
Part No.: 24B596, Series C: AC Power
Important Safety Instructions
Read all warnings and instructions in this
manual. Save these instructions.
ti14059
EN
Vista de pagina 0
1 2 3 4 5 6 ... 35 36

Indice de contenidos

Pagina 1 - Lubrication Controller

InstructionsGLC 4400 Lubrication Controller313855HFor controlling and monitoring single-line resistive, parallel, series progressive and dual line, au

Pagina 2 - Warnings

Installation 10 313855HFIG. 7GLC 4400ExternalLow LevelAlarmRemote Manual RunMachine Count SwitchLow LevelSwitchPumpReservoirInjector SystemPressureSwi

Pagina 3 - Component Identification

Installation313855H 11System WiringNOTE: On an AC controller (p/n 24B596), the J7 strip is line (input) voltage but the J6 strip is all 24VDC. On a DC

Pagina 4

Installation 12 313855HPump ON = Time; Pump OFF = Time 9 - 30VDC 100VAC/240VAC FIG. 11 *Dry Contact, FIG. 8 shown. For other configuration, see FIG. 9

Pagina 5 - Installation

Installation313855H 13System WiringPump ON = Cycle or Pressure; Pump OFF = Time9 - 30VDC 100VAC/240VAC FIG. 13 *Dry Contact, FIG. 8 shown. For other c

Pagina 6 - Grounding

Installation 14 313855HSystem WiringPump ON = Cycle or Pressure; Pump OFF = Machine Count9 - 30VDC 100VAC/240VAC FIG. 15 Dry Contact, FIG. 8 shown. Fo

Pagina 7 - Table 3: Modes of Operation

Installation313855H 15System Wiring OptionsAll Units: Low Level Switch / External Manual Run / O.K. Contact OutNOTICEDo not connect any of the SW+ (13

Pagina 8 - Divider Valve System

Installation 16 313855HSystem Wiring Options: Alarm Out9 - 30VDC100/240VACFIG. 18FIG. 1916 (SW-)15 (SEN4)14 (IN4)13 (SW+)12 (SW-)11 (SEN3)10 (IN3)9 (S

Pagina 9 - Reverser

Setup313855H 17SetupWhen you first turn on power to the Lubrication Control-ler, the following identification screen displays. A Display Contrast Adju

Pagina 10 - Injector System

Setup 18 313855H8. If the PIN Code you entered is correct, the System Setup Screen, shown in FIG. 22 displays.9. If the PIN Code you entered is incorr

Pagina 11 - System Wiring

Setup313855H 197. Press ENTER.8. Select TIMER from the pull-down list.9. Press RESET. The Main Screen displays.NOTE: When TIMER is selected, the Timer

Pagina 12 - 100VAC/240VAC

Warnings 2 313855HWarningsThe following warnings are for the setup, use, grounding, maintenance, and repair of this equipment. The exclama-tion point

Pagina 13

Setup 20 313855HCycle Mode SelectionIf the Cycle Mode is selected you will also be prompted to set the desired number of cycles.NOTE: A cycle is equal

Pagina 14

Setup313855H 21If TIME is selected: If TIME is selected you will also be prompted to set the specific amount of time.1. Use the Arrow keys to move the

Pagina 15 - System Wiring Options

Setup 22 313855H4. Use the RIGHT arrow to move the cursor to the next field. Repeat step 3.NOTE: The maximum number of Counts you can setup in this fi

Pagina 16 - 100/240VAC

Setup313855H 23Second: At Power Up, a delay occurs, the pump is off; then the normal lube cycle that was in process when power was removed, is resumed

Pagina 17 - System Setup - PIN Mode

Setup 24 313855H5. From the pull-down menu, select ON.6. Press ENTER.7. Use the Arrow keys to move the cursor over the DELAY TIME field.8. Press ENTER

Pagina 18 - System Setup

Setup313855H 2510. Use the Arrow keys to move the cursor over the TIME ON field.11. Press ENTER.NOTE: The time is displayed in Seconds.12. Use the UP/

Pagina 19 - 313855H 19

Setup 26 313855HDISPLAY Setup1. Use the UP/DOWN Arrow keys to move the cursor over DISPLAY.2. Press ENTER to display the DISPLAY setup screen.Display

Pagina 20 - PUMP OFF Setup

Setup313855H 27Quick Cycle Screen SetupThe Quick Cycle screen setup is used to setup a Trou-bleshooting profile. 1. Use the Arrow keys to move the cur

Pagina 21 - 313855H 21

Setup 28 313855HLow Level Filtering Screen SetupThe Low Level Filtering screen setup is used to filter out spurious signals from rotating paddle type

Pagina 22 - POWER UP Setup

Run Mode313855H 29Run ModeWhen you first turn the Lubrication Controller power on, the identification screen shown in FIG. 53 displays. A Display Cont

Pagina 23 - 313855H 23

Component Identification313855H 3Component IdentificationKeypad, Display, and IconsRun Mode FunctionsDirection ArrowsA Up and Down Arrow Keys: Adjusts

Pagina 24 - PULSED Setup

Run Mode 30 313855HPrelube Power Up If Prelube is enabled (page 22), the programmed pre-lube sequence occurs. If no Prelube sequence has been selected

Pagina 25 - PIN Setup

Run Mode313855H 31Pump On Ended with Cycle Switch ActivationIf the Pump On sequence has been programmed to end by a Cycle Switch Activation:• The GLC

Pagina 26 - QUICK CYCLE Setup

Run Mode 32 313855H• The GLC 4400 pump output relay activates (J7-3) and will stay off until the correct number of counts (J6-15) occur (see Setup Men

Pagina 27 - LOW LEVEL FILTERING Setup

Troubleshooting313855H 33TroubleshootingProgram SettingsDescription Problem SolutionTimer fails to activate solenoidNo power supplied to solenoidPower

Pagina 28 - 28 313855H

Technical Data 34 313855HTechnical Data Input Contact Power Source DC - model 24B591 9 - 30 VDCPower Source AC - model 24B596 100 VAC to 240 VAC - 50/

Pagina 29 - Run Mode

Dimensions313855H 35Dimensions Mounting Hole Layout4.8 in. (122 mm)4.72 in.(120 mm)3.58 in.(90.85 mm)4.17 in. (105.92 mm) 3.23 in.(82.0 mm)

Pagina 30 - Pump On Ended with Pressure

All written and visual data contained in this document reflects the latest product information available at the time of publication. Graco reserves th

Pagina 31 - Pump Off Ended with Time

Component Identification 4 313855HIconsThe following icons are used throughout this instruction manual and on the Controller’s Run and Setup Screens.

Pagina 32 - Alarms Screen

Installation313855H 5InstallationTypical InstallationThe installation shown in FIG. 2 is only a guide for selecting and installing system components.

Pagina 33 - Troubleshooting

Installation 6 313855HInstalling the Lubrication Controller1. Select a flat surface to install the Lubrication Con-troller. Drill mounting holes. Refe

Pagina 34 - Technical Data

Installation313855H 7System Configuration and WiringThe System Configuration Diagrams (FIG. 5 - FIG. 7), Sensor Wiring Diagrams (FIG. 8 - FIG. 10) and

Pagina 35

Installation 8 313855HSystem ConfigurationFIG. 5GLC 4400ExternalLow LevelAlarmRemote Manual RunMachineCount SwitchLow LevelSwitchPumpReservoirMaster D

Pagina 36 - Graco Information

Installation313855H 9FIG. 6GLC 4400ExternalAlarmCycleMachineCountExternalLow LevelAlarmExternal O.K.Low LevelSwitchPumpReservoirDual Line SystemCycleS

Comentarios a estos manuales

Sin comentarios