Modbus and I/O Data
26 312785C
Alarm Processing
See FIG. 29, Table 1, Table 2, and Table 3.
F
IG. 29. Alarm Processing Flow Chart
Alarm Processing
Is Mix Ready
bit = 1?
Check if Potlife
Alarm: is Alarm_
Potlife bit = 1?
YESNO
NO YES
An Alarm Condition
has been found
previously.
Alarm_General = 1.
Two options:
Purge or Color Change to remove
mixed material in the line.
Place in Mix mode and spray the
Potlife Volume set in the ProMix
2KS.
NOTE: The Reset key only silences
the alarm. To clear the alarm you must
use one of these two options.
Go to next process,
as desired.
Determine the exact alarm
from Table 3 on page 29
and solve what caused the
alarm, as required.
Reset the alarm.
Reset_Alarm = 1.