Grounding
The equipment must be grounded. Grounding reduces
the risk of static and electric shock by providing an
escape wire for the electrical current due to static build
up or in the event of a short circuit.
Pump: use ground wire and clamp (supplied). Loosen
grounding lug locknut and washer. Insert ground wire
end into lug slot and tighten locknut securely. Connect
ground clamp to a true earth ground.
Air and fluid hoses: use only electrically conductive
hoses with a maximum of 500 ft. (150 m) combined
hose length to ensure grounding continuity. Check elec-
trical resistance of hoses. If total resistance to ground
exceeds 29 megohms, replace hose immediately.
Air compressor: follow manufacturer’s recommenda-
tions.
Dispense valve: ground through connection to a prop-
erly grounded fluid hose and pump.
Fluid supply container: follow local code.
Solvent pails used when flushing: follow local code.
Use only conductive metal pails, placed on a grounded
surface. Do not place the pail on a nonconductive sur-
face, such as paper or cardboard, which interrupts
grounding continuity.
To maintain grounding continuity when flushing or
relieving pressure: hold metal part of the dispense
valve firmly to the side of a grounded metal pail, then
trigger the valve.
Integrated Air Controls
The integrated air controls include:
• Main air slider valve (BA): turns air on and off to
the system. When closed, the valve relieves pres-
sure downstream.
• Ram air regulator (BB): controls ram up and down
pressure and blowoff pressure.
• Ram director valve (BC): controls ram direction.
• Exhaust port with muffler (BD)
• Air motor regulator (BE): Controls air pressure to
motor.
• Air motor slider valve (BF): turns air on and off to
the air motor. When closed, the valve relieves air
trapped between it and the air motor. Push the valve
in to shutoff. Remote DataTrak: The air solenoid
(Y, F
IG. 2), the air motor slider valve (BF), and the
main air slider valve (BA) must be open for air to
flow. (See Remote DataTrak Setup section in Supply
Systems operation manual 313526.)
• Blowoff button (BG): turns air on and off to push
the platen out of an empty drum.
Air Line Accessories
See FIG. 2.
• Air line drain valve (U)
• Air line filter (V): removes harmful dirt and mois-
ture from compressed air supply.
• Second bleed-type air valve (W): isolates air line
accessories and supply system for servicing. Locate
upstream from all other air line accessories.
• Air relief valve (attached to ram air regulator, not
visible): automatically relieves excessive pressure.