Appendix A - User Interface Display
313528E 35
Hardware Setup Screens
The Hardware Setup screens enable users to specify if
specific hardware is installed on the system and to
adjust hardware settings. Press to scroll
through the Hardware Setup screens. Once in the
desired Hardware Setup screen, press to access
the fields to make changes. Press to exit edit
mode.
NOTE: Must exit edit mode to scroll through the
Hardware Setup screens.
Hardware Setup Screen 1
This screen enables users to specify if a fluid filter moni-
tor is installed, and set the high and low limits for the
pressure drop across the filter.
Monitor the filter pressure readings through the normal
range of flow with a clean filter to establish the initial limit
settings.
Hardware Setup Screen 2
This screen enables users to specify if a fluid solenoid is
installed, and if a drum low sensor is installed. The fluid
solenoid controls the depressurize/recirculate valve.
Icon Function
Select what type of error will be issued if fil-
ter pressure drops below the low limit or
raises above the high limit. Select to
disable filter monitoring or if there is no fil-
ter installed on the system.
Set low limit (0-1000 psi) for pressure drop
that will issue an error. Set the low limit to
detect a filter element collapse or a missing
element.
Set high limit (0-5000 psi) for pressure drop
that will issue an error. Set the high limit to
detect a clogged filter.
FIG. 23: Hardware Setup Screen 1 (Filter)
Icon Function
Select if fluid solenoid is installed on sys-
tem. Set for A and B rams.
Select if drum low sensor is installed on
system. Set for A and B rams.
F
IG. 24: Hardware Setup Screen 2