Alarms
313528E 29
Fluid Control Module (continued)
DA1X
DA2X
Pump Runaway A
Pump Runaway B
Pump is running faster than
set runaway limit due to:
• Increased air pressure.
• Increased fluid output.
• Exhausted fluid supply.
• Open fitting, hose, drain,
or bleed valve.
Correct runaway condition
and clear alarm.
Cleared from Ram Alarm
screen. See Appendix A -
User Interface Display,
page 31.
L11X
L12X
A - Drum Empty
B - Drum Empty
Drum empty sensor has been
activated.
Replace empty drum with
full drum to clear.
Alarm automatically
cleared by solution.
DB1X
DB2X
A - Not Primed
B - Not Primed
The pump is not primed. Set ram to Prime mode to
automatically clear alarm,
or manually clear alarm
from Ram Alarm screen.
Cleared from Ram Alarm
screen or Ram Operation
screen. See Appendix A -
User Interface Display,
page 31.
WJ1X
WJ2X
A - Air Solenoid Discon-
nected
B - Air Solenoid Discon-
nected
Solenoid unplugged. Check that solenoid cable
is connected.
Alarm automatically
cleared by solution.
Damaged solenoid / wires. Inspect solenoid wires for
damage.
Alarm automatically
cleared by solution.
DK1X
DK2X
A - Air Motor Sensor Error
B - Air Motor Sensor Error
System has seen multiple up
strokes without a down stroke,
or multiple down strokes with-
out an up stroke.
See air motor manual. Cleared from Ram Alarm
screen. See Appendix A -
User Interface Display,
page 31.
Damaged or disconnected air
motor sensors.
Check that air motor sen-
sors are connected.
Inspect air motor sensor
harness for damage.
L21X
L22X
A - Drum Low Deviation
B - Drum Low Deviation
Drum low sensor has been
activated.
Replace empty drum with
full drum to clear.
Deviation automatically
cleared by solution.
WK1X
WK2X
A - Fluid Solenoid Discon-
nected Deviation
B - Fluid Solenoid Discon-
nected Deviation
Solenoid unplugged. Check that solenoid cable
is connected.
Deviation automatically
cleared by solution.
Damaged solenoid wires. Inspect solenoid cable for
damage.
ML1X
ML2X
A - Rebuild Platen Seals
B - Rebuild Platen Seals
Counter has reached pro-
grammed platen maintenance
interval.
Perform platen mainte-
nance; see Supply Sys-
tems Repair-Parts manual.
Cleared from Maintenance
screen. See Appendix A -
User Interface Display,
page 31.
MA1X
MA2X
A - Rebuild Pump
B - Rebuild Pump
Counter has reached pro-
grammed pump maintenance
interval.
Perform pump mainte-
nance. See Check-Mate
Displacement Pump man-
ual.
Cleared from Maintenance
screen. See Appendix A -
User Interface Display,
page 31.
Alarm
Code Alarm Problem Cause Solution Clear Alarm