Alarms
28 313528E
Alarms
Supply system alarms alert you to a problem and help
prevent system shutdown or application errors. If an
alarm occurs, operation may stop and the following
occurs.
Light tower indication changes (if equipped)
Status bar on the display shows the alarm descrip-
tion
Diagnose Alarms
See Alarm Codes and Troubleshooting, page 28, for
causes and solutions to each alarm code.
Clear Alarms
Alarms are cleared by the solution(s) listed in the follow-
ing table or from the screen in which they appear. Refer
to Alarm Codes and Troubleshooting, page 28, for
details.
Alarm Codes and Troubleshooting
Alarm
Code Alarm Problem Cause Solution Clear Alarm
Fluid Control Module
CB1X A - Communication Error -
Ram A Not Found
Ram cannot communicate with
FCM A.
Verify that power is sup-
plied.
Alarm automatically
cleared by solution.
Check that CAN cables are
connected.
Verify that selector switch is
set correctly.
Replace FCM A.
CB2X B - Communication Error -
Ram B Not Found
Ram cannot communicate with
FCM B.
Verify that power is sup-
plied.
Alarm automatically
cleared by solution.
Check that CAN cables are
connected.
Verify that selector switch is
set correctly.
Replace FCM B
B61X
B62X
Crossover Error (Ram A)
Crossover Error (Ram B)
Inactive ram has a Not Primed
alarm.
Set inactive ram to Prime
mode to automatically clear
alarm.
Cleared from Ram Alarm
screen. See Appendix A -
User Interface Display,
page 31.
There is a Runaway alarm Correct runaway condition
and clear alarm on Status
screen 1.
There is a Drum Empty alarm. Replace empty drum with
full drum to clear.