Electronic Crossover Operation
313528E 25
Automatic Crossover
The automatic crossover feature allows continuous flow
and prevents system shutdown. If the active ram
encounters a pump runaway, drum empty, or air sole-
noid disconnected alarm it will attempt an automatic
crossover to the inactive ram.
The system will generate a crossover error if the active
ram attempts an automatic crossover while the inactive
ram has a pump runaway, drum empty, air solenoid dis-
connected, or not primed alarm.
Manual Crossover
Manual crossover can only be initiated if the following
conditions are met:
• inactive ram is not in the drum empty error condi-
tion.
• pump runaway and not primed alarms do not exist.
To initiate a manual crossover to the inactive ram:
1. From the Ram Operation screen, press the Cross-
over key . The display prompts the operator to
confirm.
2. Select to confirm manual crossover operation
or select to cancel.
NOTE: If the active ram has a pump runaway error or
drum empty error, the system will attempt an auto-
matic crossover.
Keep clear of the inactive ram, as automatic cross-
over may occur unexpectedly. To repair or adjust the
ram, first follow all steps of the Pressure Relief Pro-
cedure on page 22.
FIG. 15: Crossover Function Screen