Appendix A - User Interface Display
313528E 39
Status Screen
This screen displays the job totals and grand totals. If
there is a filter or an error issued, there will be additional
screens. Press to scroll to through the
Status screens.
NOTE: If an alarm is issued, the Alarm screen will be
the first status screen shown.
To reset a job total for a single ram (A or B), press
to access the fields, navigate to the value, and press
. When prompted, press to confirm. If the job
total is reset, A and B totals will also be reset. Press
to exit edit mode.
NOTE: Grand totals cannot be reset.
Alarm Screen
The alarm screens display the type of alarm currently
occurring on each ram. Once an alarm is resolved, use
this screen to clear the alarm.
NOTE: For more information regarding alarms. See
Alarms on page 28.
To clear an alarm, press to access the fields, navi-
gate to the alarm icon, and press . When
prompted, press to confirm. Press to exit edit
mode.
Icon Function
Job total column; indicates pump cycle
count total for a single job.
Grand total column; indicates pump cycle
count total for all jobs.
Displays pump cycle count for Ram A for
a single job and all jobs.
Displays pump cycle count for Ram B for
a single job and all jobs.
Displays pump cycle count for entire sys-
tem for a single job and all jobs.
F
IG. 30: Status Screen 1
Icon
Alarm
Code Function
B61X
B62X
Crossover Error
A crossover to a pump with an
error was attempted.
DA1X
DA2X
Pump Runaway
Pump is running faster than the
runaway limit.
DB1X
DB2X
Pump Not Primed
A new drum has not been
primed.
DK1X
KD2X
Air Motor Sensor Error
Air motor sensor detects a fault
in the pump motion.
DD1X
DD2X
Pump Diving
Pump leak or ram air pressure is
too low.
L11X
L12X
Drum Empty
Drum for ram A or ram B is
empty.
F
IG. 31: Ram Alarm Screen
Comentarios a estos manuales