Electronic Crossover Operation
24 313528E
Prime
1. Make sure the system is at required temperature.
2. To prime the active ram, ensure that the system is
on and not in Run Mode. To prime the inactive ram,
ensure that the system is on and in Run Mode.
3. If using a manual dispense valve, unlock the dis-
pense valve trigger and place dispense valve over a
waste container.
4. Press the Pump Prime key . The display
prompts the operator to confirm. See F
IG. 12. Select
to begin prime.
5. When the timer expires the air motor solenoid LED
will turn off.
6. Prime the system until a smooth flow of material dis-
penses from the dispense valve.
7. Lock the dispense valve trigger lock.
NOTE: To exit Prime Mode before the timer expires,
press the Pump Prime key . The display
prompts the operator to confirm. See F
IG. 13. Select
to exit prime.
NOTE: To extend the prime time counter, select
in F
IG. 13. Display prompts operator to confirm. See
F
IG. 14. Select to reset.
FIG. 11: Ram Operation Screen - Tandem System
F
IG. 12: Prime Confirmation
FIG. 13: Exit Prime Mode Confirmation
F
IG. 14: Reset Prime Time Counter Confirmation
Comentarios a estos manuales