Appendix A - User Interface Display
313528E 33
Setup Mode Screens
Setup mode screens are divided into six sections: pass-
word, system setup, heat zone setup, maintenance
setup, hardware setup, and advanced setup.
Password Screen
While in Run mode, press the Setup button. If the
password is not set to 0000, the Password screen will
appear. Enter the password to continue to Setup mode.
NOTE: Upon the first system startup, the System
Setup screen will display. Otherwise, the last setup
screen viewed will display.
Set Password
To set the password, press to enter the screen.
Press to select digit to change. Press
to set value for each digit. Press
again to enter the password.
System Setup
The System Setup screen enables users to configure
system settings for the ram(s). Press to access the
fields and make changes. Press to exit edit mode.
F
IG. 20: Password Screen
Icon Function
Select tandem operation, ram A only oper-
ation, or ram B only operation.
Select if a Not Primed event will issue an
alarm or deviation.
Set number of minutes (1-9) for priming.
Set pump cycles per minute that will issue
a pump runaway alarm. Set between 0 and
99; default setting is 60 cycles; 00 setting
disables this function.
F
IG. 21: System Setup