Graco 313528E Manual de usuario Pagina 41

  • Descarga
  • Añadir a mis manuales
  • Imprimir
  • Pagina
    / 46
  • Tabla de contenidos
  • MARCADORES
  • Valorado. / 5. Basado en revisión del cliente
Vista de pagina 40
Appendix A - User Interface Display
313528E 41
Filter Screen
NOTE: The filter screen is only available if the fluid
filter option is enabled. See Hardware Setup Screen
2, page 35.
This screen displays the fluid filter inlet pressure, outlet
pressure, and the differential pressure across the filter.
Over or Under Pressure Alarm
If the differential pressure measured across the fluid fil-
ter for at least five strokes is greater than the high limit or
less than the low limit value set in the Hardware Setup
Screen 1, and alarm or deviation is indicated; see F
IG.
34. Whether an alarm or deviation is issued depends on
the error type set in the Hardware Setup Screen 1.
To clear a filter alarm or deviation, press from the
fluid filter screen. Then press on the confirmation
screen.
Icon Function
Fluid filter inlet pressure.
Fluid filter outlet pressure.
Differential pressure across the fluid filter.
F
IG. 33: Fluid Filter Screen
FIG. 34: Fluid Filter Screen with Alarm
F
IG. 35: Fluid Filter Screen with Alarm