Electronic Crossover Operation
313528E 27
Shutdown
Follow the procedure below for normal system shut
down, such as at the end of the work day.
NOTE:
The ram up/down and blowoff air is independent of
the electronic controls and can be operated anytime
the main air slider valve is open and air pressure is
available.
1. Press while in the Ram Operation screen to
turn off the air motor. Select to confirm.
2. Press while in the Heater Run screen to turn
off the heaters. Select to confirm.
3. Follow the Pressure Relief Procedure, page 22.
Turning the system OFF relieves pressure from the
pump motor. It does not depressurize the fluid pres-
sure. Follow the Pressure Relief Procedure, page
22.