Graco 313528E Manual de usuario Pagina 34

  • Descarga
  • Añadir a mis manuales
  • Imprimir
  • Pagina
    / 46
  • Tabla de contenidos
  • MARCADORES
  • Valorado. / 5. Basado en revisión del cliente
Vista de pagina 33
Appendix A - User Interface Display
34 313528E
Maintenance Setup Screen
The Maintenance Setup screen enables users to set
maintenance intervals for rebuilding platen seals and
rebuilding the pump.
Icon Function
Set the number of drums (0-9999) between
platen seal maintenance. Setting the num-
ber of pump cycles to 0 disables this func-
tion. If using a tandem system, set for each
ram. A rebuild platen seals error is issued
when maintenance is required. See Alarm
Codes and Troubleshooting on page 28.
Set the number of pump cycles (0-9999)
between pump maintenance. Setting the
number of pump cycles to 0 disables this
function. If using a tandem system, set for
each pump. A rebuild pump error is issued
when maintenance is required. See Alarm
Codes and Troubleshooting on page 28.
F
IG. 22: Maintenance Setup
Vista de pagina 33
1 2 ... 29 30 31 32 33 34 35 36 37 38 39 ... 45 46

Comentarios a estos manuales

Sin comentarios